Product Details:
|
| OEM Part: | 2021406-001 | Material: | Medical TPU |
|---|---|---|---|
| Patient End: | DB9 | Monitor Connector: | 11Pin |
| Length: | 2.4M | Sample: | Available |
| Package: | 1 Pc In Bag | Service: | OEM&ODM |
| Warranty: | 6 Month Repair For Free | Color: | Grey |
| Application: | Patient Monitor,pulse Oximeter | Shipping: | DHL/Fedex/UPS/TNT/EMS |
| Highlight: | Marquette Spo2 Extension Cable,GE Healthcare 2021406-001,Spo2 Extension Cable 11Pin |
||
1.Description:GE Healthcare > Marquette Compatible SpO2 Adapter Cable - 2021406-001
| P/N | Description | Instrument connector | Sensor side connector | |
| MPE010F | GE11P-DB9F, For Nellcor Oximax |
![]() |
![]() |
|
| MPE010H | GE11P-DB9F, for Nellcor No-Oximax |
![]() |
|
|
2.OEM Part Number Cross References
| Manufacturer | OEM Part # |
|---|---|
| Curbell | 5590 (CB-A400-3300) (8 ft) |
| GE Healthcare > Marquette | 2021406-001, 2025350-001, 2021406-002 (4 ft (1.2 m)) |
| Pacific Medical | NXMQ101, NXMQ4526 |
| Sage | E02X-36M |
| Tenacore | TE2425 |
3.Compatibility
| Manufacturer | Model |
|---|---|
| GE Healthcare > Corometrics | 128, 250, 250cx, 259 Fetal Monitor with Oximax technology, TRAM 450SL |
| GE Healthcare > Critikon > Dinamap | B105, B125, Carescape B450, Carescape B650, Carescape B850, Carescape V100 |
| GE Healthcare > Marquette | Dash 2500, Dash 3000, Dash 4000, Dash 5000, Dash Series, Eagle, PDM Module, Procare B40, SOLAR, Solar 8000, Solar 8000M, TRAM Modular, Tram 451, i/9500, x50SL Series |
4.Specification
| Connector type | 11Pin |
| Cable material | medical TPU |
| Cable diameter | 4.0 cable |
| Patient end | DB9 Female |
| Latex Free | Yes |
| OEM&ODM Service | Yes |
| Cable length | 2.4M |
| Certificate | ISO13485,CE |
| Application | extend Spo2 sensor |
| Package | 1 piece in bag |
5.Advantage:
-Mainly used in.: Nellcor Oximax SpO2 Probe;
-Monitor Conn.: 11Pin;
-Patient Conn. No.:DB9pin;
-Length of Probe: 2400MM ± 50MM;
-Material of Cable: TPU safety cable;
-Advantage of Cable: High quality alloy conductors with KEVLAR® reinforcement fibers for durability;
-Advantage of Pin: Gold-plated terminals(pin), for strengthen the signals’s conductivity without interference.
-Design to prevent the lid off, Effective protection of cables to connect;
-Certificate of Product: CE authentication;
-Guarantee of Product: Providing the quality assurance for 6 month, Non-human damage!